OPERATIONAL
Light Source Visible Laser Diode 650 nm
Laser Power 1.1 mW (peak)
Depth of Scan Field
19 mm - 273 mm (.75” - 10.75”) for 0.33 mm (13 mil) barcode at default setting
Width of Scan Field 30 mm (1.2”) @ 25 mm (1.0”); 150 mm (5.9”) @ 280 mm (11.0”)
Scan Speed Omnidirectional - 1650 scan lines per second
Raster - 320 scan lines per second
Single-line - 80 scan lines per second
Scan Pattern Omnidirectional - 5 fields of 4 parallel lines
Raster - 4 lines
Single-line - 1 line
Minimum Bar Width 0.127 mm (5.0 mil)
Decode Capability Autodiscriminates all standard 1D bar codes, including RSS Expanded, RSS-14 and RSS-14 Limited; for other symbologies call Metrologic
System Interfaces RS232, Light Pen Emulation, Keyboard Wedge, Stand Alone Keyboard, IBM 468x/469x, USB, Laser Emulation, OCIA
Print Contrast 35% minimum reflectance difference
Roll, Pitch, Yaw 360°, 60°, 60°
Beeper Operation 7 tones or no beep
Number Characters Read Up to 80 data characters
(maximum will vary based on symbology and density)
Indicators (LED) Blue = laser on, ready to scan White = good read
MECHANICAL
Length
Width
Height
66 mm (2.60”)
67 mm (2.65”)
108 mm (4.25”)
Weight (scanner)

170 g (6.0 oz)

Cable (Host)

RS232, Light Pen Emulation, Keyboard Wedge, Stand Alone Keyboard, IBM 468x/469x, USB, Laser Emulation, OCIA

ELECTRICAL
Input Voltage 5 VDC + 0.25 V
Power

1.375 W

Current Operating
275 mA typical @ 5 VDC
DC Transformers Class 2; 5.2 VDC @ 650 mA
Laser Class Class 1; IEC60825-1:1993/A1:1997+A2:2001
Class 1; EN60825-1:1994/A11:1996+A2:2001
EMC FCC, ICES-003 & EN55022 Class A
ENVIRONMENTAL
Operating Temperature -20°C to 40°C (-4°F to 104°F)
Storage Temperature -40°C to 60°C (-40°F to 140°F)
Humidity 5% to 95% relative humidity, non-condensing
Light Levels Up to 4842 Lux (450 footcandles)
Shock Designed to withstand 1.5 m (5') drops
Contaminants Sealed to resist airborne particulate contaminants
Ventilation None required