Click here to go directly to our homepage.
OPERATIONAL
Light Source Visible laser diode 650 nm ± 10 nm
Laser Power 0.900 mW (peak)
Depth of Scan Field
0 mm – 255 mm (0” – 10”) for 0.33 mm (13 mil) bar code
Width of Scan Field 100 mm (4’’) @ 0 mm; 323 mm (12.7’’) @ 255 mm (10.0’’)
Scan Speed 1800 scan lines per second
Scan Pattern 5 fields of 4 parallel lines (omnidirectional)
Minimum Bar Width 5 mil (0.127 mm)
Decode Capability Auto-discriminates all standard bar codes, including GS1 DataBarTM; for other symbologies call Metrologic
System Interfaces RS232, Keyboard wedge, USB, IBM 468x/469x
Print Contrast 35% minimum reflectance difference
Roll, Pitch, Yaw 360°, 60°, 60°
Beeper Operation 7 tones or no beep
Number Characters Read Up to 80 data characters
(maximum will vary based on symbology and density)
Indicators (LED) Blue = unit powered, ready to scan; Blue flash = good read, button activation; 7-segment display = failure diagnostic
MECHANICAL
Length (scanner only)
Width (scanner only)
92 mm (3.6”)
152 mm (6.0”)
Height (scanner only) 152 mm (6.0”)
Weight 0.7 kg (1.56 lbs)
Cable (Host)

USB, RS232, Keyboard wedge, IBM 46xx (RS485)

ELECTRICAL
Input Voltage 12 VDC ± 0.25 V
Power Standby

1.2 W (100 mA @ 12 V) - typical

Current Operating
3.8 W (320 mA @ 12 V) - typical; 4.8 W (400 mA @ 12 V) - typical with AUX hand-held scanner
DC Transformers Class 2: 12 VDC @ 1.25 A
Laser Class Class 1: IEC60825-1, EN60825-1
EMC FCC Part 15, IEC-003, EN55022 Class B
ENVIRONMENTAL
Operating Temperature 0°C to 40°C (32°F to 104°F)
Storage Temperature -40°C to 60°C (-40°F to 140°F)
Humidity 5% to 95% relative humidity, non-condensing
Light Levels Up to 4842 Lux (450 footcandles)
Shock Designed to withstand 1.5 m (5') drops
Contaminants Sealed to resist airborne particulate contaminants
Ventilation None required


©POS Peripherals Inc.