Mechanical
Dimensions: 2.7 x 4.4 x 7.2" / 6.9 x 11.2 x 18.3 cm
Weight Scanner: 9.9 ozs. / 280 g; Cable (32"/82,3 cm): 6.2 ozs. / 176 g
Cable length options: Collapsed: 32" / 81 cm, Max. Working: 72" / 183 cm; Collapsed: 80" / 203 cm, Max. Working: 120" / 305 cm
Optical
Light source: Extra Bright 650nm Visible Laser Diode (VLD)
Scan system: Frictionless lifetime flexure mechanism
Rate: 37 scans/sec. nominal
Print contrast ratio: 25% minimum
Pitch: ±65°
Skew: ±55°
Ambient light immunity Artificial light: 1,200 foot candles / 12912 Lux; Sunlight: 8,000 foot candles / 86080 Lux
Electrical
Operating voltage: 4 VDC to 14 VDC
Operating current – nominal; Undecoded: 75mA @ 5 VDC; Decoded: 100mA @ 5 VDC
Idling current – low power mode: <50µA @ 5 VDC
Environmental
Temperature rating Operating: -22° to 122° F / -30° to 50° C; Storage: -40° to 158° F / -40° to 70° C
Humidity: 5 to 95% NC
Shock (at 23°C): withstands multiple 6.5’ / 2 m drops to concrete
Vibration: meets MIL-STD-810E
Water & Dust: IEC529 rating IP54DW
Decoding Capability
autodiscriminates between)UPC A, E / EAN 8,13 / JAN 8, 13 (P2 / P5, Code 128 EAN add-ons)Code 128 Codabar Pharmacode 39 Code 39 Full ASCII Code 39 Code 93 Interleaved 2 of 5 Standard 2 of 5 MSI / Plessey BC412
Communications
Undecoded: Standard and Intermec-compatible Multi-interface modules (interchangeable, AutoSelectTM cable determines active interface): RS232C / Standard Keyboard Wedge / Wand Emulation Universal Keyboard Wedge / RS232* IBM 46XX / RS232C *This RS232 interface only supports RXD and TXD, no control signals are available.
Safety & Regulatory
Electrical: Complies to Gost R; TÜV; UL; cUL
Emissions: Complies to FCC-A; EN 55022-B BCIQ CNS13438; AS/NZS 3548; VCCI-B
Laser classification: CDRH Class II; (CAUTION: Laser Radiation – do not stare into beam); IEC 60825 Class 2